Exceptional, high-end reflectance measurements

This high-precision, close-tolerance, reference grade spectrophotometer has special capabilities to handle fluorescent materials.
  • Exceptional inter-instrument agreement
  • Easy maintenance
  • Exceptional stability
  • Automated zoom lens and specular port
  • Automated UV control
  • Multiple viewing apertures with automatic aperture recognition
  • Automactic gloss compensation
 

Features

Full Agreement

You can be confident of full agreement throughout Datacolor’s entire family of sphere instruments.

Exceptional Stability

Exceptionally low drift means more stability, so you can recalibrate less often, increasing productivity.

User-Friendly

Our intuitive design makes it easier to understand status indicators, reducing the chance of error in instrument setup and operation.

Fast, Easy Maintenance

Datacolor instruments seldom require service. When they do, service is faster and easier because of fewer components and full data compatibility. And, our advanced technology ensures the ability to reproduce the same results you obtained before the service.

Software Compatibility

Datacolor spectrophotometers are designed for use with our award-winning software. They are also compatible with virtually all color packages. So, with this combination of flexibility, precision, and performance you get an unbeatable package.

High-precision, close-tolerance, reference grade spectrophotometer with capability to handle fluorescent measurements

Automated zoom lens and specular port

Exceptional inter-instrument agreement

Automated UV control

Multiple viewing apertures with automatic aperture recognition

Automatic gloss compensation

Superior sensor technology can output data at 5nm or 10 nm intervals

Datacolor spectrophotometers provide high resolution color measurement and excellent short and long-term repeatability

The 3.0 mm aperture can measure unusually small sample areas

The exceptionally large (30mm) aperture means you can maximize the surface area to be measured – ideal when measuring color without regard to a textured surface

Specifications

Technical specifications

Feature

Description

Instrument Type Dual-beam spectrophotometer
Measurement Geometry Diffuse illumination and 8° viewing
Illumination Source Pulsed xenon filtered to approximate D65
Sphere Diameter 152 mm / 6.0 in
Specular Port Automated included or excluded
Spectral Analyzer Proprietary SP2000 analyzer with dual 256 diode array and high resolution holographic grating
Transmittance Measurements No
Wavelength Range 360 nm to 700 nm
Reporting Interval 5 nm or 10 nm(1)
Effective Bandwidth 5 nm or 10 nm
Photometric Range 0 to 200%
Black Trap High performance
20 Read Repeatability On The White Tile Using Dual Flash (CIELAB) 0.01 (max)
Inter-instrument Agreement(2) for Reflectance (CIELAB) 0.15 (max) , 0.08 (avg)
Inter-instrument Agreement(2) for Regular Transmittance at 550 nm Not available
Inter-instrument Agreement(2) for Diffuse Transmittance at 550 nm Not available
Inter-instrument Agreement(2) for Transmission Haze Measurements Not available
Lens 4 position auto zoom
Aperture plates for reflection measurements 3 standard (LAV, SAV, USAV)
2 optional (XUSAV)
LAV 30 mm illuminated
26 mm measured
MAV 20 mm illuminated
16 mm measured
SAV 9 mm illuminated
5 mm measured
USAV 6.6 mm illuminated
2.5 mm measured
XUSAV(3) 3.0 mm illuminated
2.5 mm measured
Reflection Aperture Plate Detection Yes
Transmission Sampling Aperture Size Not available
UV Calibration Yes
Automatic UV Control Automatic UV calibration for the measurement of fluorescent Specimens with UV cutoff filters at 400 nm, 420 nm and 460 nm
Instrument-mounted Measure Switch Yes(4)
Vertical Mount Optional (5)
Power Requirements 85 to 264 VAC, 47 to 63 Hz, 80 VA peak, 35 VA typical
Absolute Operating Range 5° to 40° C, 5% to 85% noncondensing relative humidity
Interface RS-232(6) or USB 1.1

1- The software must be capable of supporting 5 nm reporting.
2- Environmental conditions apply.
3- Sample translucency may affect interlens agreement.
4- The software must be capable of supporting the instrument-mounted measure switch.
5- Including peephole sample viewer.
6- The RS-232 interface is capable of 9600 to 115200 Baud and is shipped from the factory configured to 19200 Baud.

Horizontal Model Size And Weight

Metric

English

Height 325 mm 12 13/16 in
Width 312 mm 12 5/16 in
Depth 471 mm 18 5/8 in (Including Sample Holder)
Weight 14.97 kg 33 lb

Vertical Model Size and Weight

Metric

English

Height 640 mm 25 3/16 in
Width 312 mm 12 5/16 in
Depth 371 mm 14 5/8 in
Weight 19.05 kg 42 lb

Support

Language Brochure Guide
English
Chinese Simplified
French
German
Italian
Russian
Spanish

Need support for a Datacolor product?

If you need to contact Datacolor about support for a product, you can contact us a number of ways:

1. Call us at +1 800.982.6496 (U.S. Only)
2. Fax us at 609.895.7404 (US & Canada Only)
3. International, call +1 609.924.2189
4. Locate your local representative here
5. Fill out the contact form here