All models come with the following standard accessories:
- Power cable
- USB Cable with ferrite
- Black Trap
- White Tile
- Green Tile
- White Tile Calibration data on Mini-CD or USB Memory Stick
- Large Area View (LAV)
- Small Area View (SAV)
- Ultra-Small Area View (USAV)
|
Datacolor Spectro 700 |
Datacolor Spectro 700UV |
Datacolor Spectro 700V |
Datacolor Spectro 700V UV |
Datacolor Spectro 750 |
| Instrument Type |
Horizontal Benchtop Spectrophotometer |
Vertical Benchtop Spectrophotometer |
Horizontal Benchtop Spectrophotometer |
| Measurement Geometry |
Diffuse illumination 8°viewing |
| Light Source |
Pulsed xenon lamp |
| Sphere Diameter |
152 mm/6in |
| Wavelength Range |
360 nm -700 nm |
| Reporting interval |
10 nm & 5 nm* |
| Photometric range |
0-200% |
| Spectral Analyzer |
Dual 256 diode array (software wavelength calibrated) |
| Wavelength Calibration Method |
Via software adjustment |
| 20 read repeatability on white tile using double flash (CIELAB) (1) |
0.03 (max) |
| Inter-instrument agreement: reflectance measurements (CIELAB)(1, 2 & 3) |
0.15 (avg) SCI
0.30 (max) SCI |
| Sample Temperature |
LAV aperture |
| IR Sensor Accuracy |
±0.9°F/ ±0.5°C |
| Lens |
4 position auto-zoom |
| Aperture Plates |
3 standard:
LAV (30 mm illuminated, 26mm measured)
SAV (9 mm illuminated, 5 mm measured)
USAV (6.6 mm illuminated, 2.5 mm measured)
2 optional:
MAV (20 mm Illuminated, 16 mm measured)
XUSAV (3.0 mm illuminated, 2.5 mm measured) |
| Aperture detection |
|
|
|
|
|
| Automated, adjustable UV calibration |
|
|
|
|
|
| UV cutoff filters |
|
400 nm
420 nm
460 nm |
|
400 nm
420 nm
460 nm |
400 nm
420 nm
460 nm |
| Remote Measurement Button |
|
|
|
|
|
| Sample Positioning Camera |
|
|
|
|
|
| Transmittance |
|
|
|
|
Total, Diffuse and Haze Transmittance, Regular Transmittance |
| Inter-instrument agreement – regular transmittance at 550 nm |
|
|
|
|
±0.40% at 85% T
±0.20% at 32% T |
| Inter-Instrument agreement -transmission haze measurements |
|
|
|
|
±0.30% at 10% TH |
| Transmission sampling aperture size |
|
|
|
|
22 mm |
| Functional Operating Environment (2) |
Temperature: 5°C to 40°C, *Recommended Temperature: 23°C +/- 1°C, Max Relative Humidity 20%-85% non-condensing. Recommended Relative Humidity 50% +/- 15% non-condensing |
| Vertical Mount |
|
|
|
|
|
| Optional Accessories |
MAV Aperture Plate, XUSAV Aperture Plate, Textile Skein Holder, Glass Aperture Plate LAV, Cuvette (10 mm), Compression Sample Holder, 10 mm Transmission Cell, TerryCloth Fixture Kit, White Backing Tile & Grey Backing Tile |
| Physical Specifications |
| Color Display |
3.5 inch RGB LCD |
| Display Resolution |
320×240 pixel resolution |
| Power Requirements |
Input Voltage: 100-240VAC +/- 10%
Frequency: 50/60 Hz |
| Power Consumption |
80VA |
| Weight |
54.5 lbs (24.7 kg) |
44 lbs (20.0 kg) |
| Dimensions |
Height: 15.3″ (38.86 cm)
Width: 12.3″ (31.24 cm)
Front to back:
Length: 16.4″ (41.66 cm)
Sample Arm To Back:
Length 18.3″ (46.48 cm) |
Height: 25.0″ (63.5 cm)
Width: 12.2″ (39.9 cm)
Depth: 16.3″ (41.4 cm) |
Height: 15.3″ (38.86 cm)
Width: 12.3″ (31.24 cm)
Front to back:
Length: 16.4″ (41.66 cm)
Sample Arm To Back:
Length 18.3″ (46.48 cm) |
| Recommended option |
User Color Performance Monitoring Tool: Guardian |
| Data Interface |
USB: 2.0 / Ethernet |
*5 nm not normalized data (Datacolor TOOLS only)
(1) Environmental Conditions: Temperature 23°C +/- 1°C RH 50% +/- 10%
(2) For reliable color measurements, conditions must be within recommended operating conditions.
(3) Color equation is CIELab, Specular Included, LAV, Measured on 12 BCRA Tiles